| Modulus of Rupture

Compressive Strength

Modulus of Elasticity

Tensile Strength

Fire Hazard Classification

|
Standard Sizes
| Colorith HP
|
| Thickness |
3/4" |
1" |
1 1/4" |
| Width |
55" |
49" |
49" |
| Length |
98" |
98" |
98" |
1/4" and 1/2" thicknesses are available upon request
|
| Fire Hazard Classification
ASTM E 84
| Colorith HP
|
| Flame spread |
0 |
| Smoke developed |
0 |
|
Total ultimate uniform loads in pounds for
1'0" wide reagent shelves
|
Spans
|
3/4" thick
|
1" thick
|
1 1/4" thick
|
|
24"
|
800
|
1,500
|
2,660
|
|
36"
|
530
|
1,000
|
1,880
|
|
48"
|
355
|
700
|
1,260
|
|
Average Physical Properties*
| Density, dry, lbs/ft3 (min.) |
93 |
| Moisture Content, normal, % |
11 |
| Modulus of Rupture, psi |
3,150 |
| Modulus of Elasticity, psi |
1.89x106 |
| Interlaminar Strength, psi |
500 |
| Compressive Strength, psi |
7,200 |
| Water Absorption, % dry wt, 48 hr immersion |
20.0 |
| Maximum Continuous Operation Temperature, °F |
250 |
* Approximate average laboratory test values -- not for specification.
|
| General Care
The life and appearance of AFCC work surfaces can be prolonged by following
a few simple procedures:
- Clean up spilled reagents immediately.
- Wash surfaces at least once a day with soap and clean water and follow
with a clean water rinse.
- Avoid the use of steel wool and other heavy abrasives.
|
| Note:
The physical and chemical properties of AFCC 's Colorlith HP represent
typical average values obtained in accordance with accepted test methods
and are subject to normal manufacturing variations. They are supplied as
a technical service and are subject to change without notice. Check wth
AFCC's Corporate Headquarters to assure current information.
|
American Fiber Cement Corporation
6901 S. Pierce St., Ste. 260
Littleton, CO 80128
Phone: (303) 978-1199, (800)-688-8677
FAX: (303) 978-0308
Interactive Form E-mail:
info@americanfibercement.com
Web page produced by
Internet Consulting Group, Inc. 3/97
|